UBIQUITI UA-G2-SK-Pro Door Access Starter Kit. Includes 1 UA-Hub, 1 UA-G2-Pro, 1 UA-G2, 2 Pocket Key Fobs

Save 10%
SKU: UA-G2-SK-Pro
No reviews

Price:
Sale priceS/. 3,357.00 PEN Regular priceS/. 3,731.00 PEN

Shipping calculated at checkout

Stock:
In stock
VER FICHA TÉCNICA

Description

  • (1) Door bin
  • (1) G2 Pro Reader
  • (1) G2 reader for door exit or entry for an additional door (second hub required)
  • (2) Pocket Keychains

Specs

UA-Hub- Mechanical Door
Dimensions 174.9 x 126 x 32.9mm (6.9 x 5 x 1.3")
Weight 363 grams (12.8 ounces)
Enclosure material polycarbonate
Mounting material polycarbonate
Hardware
Network interface (5) 10/100/1000 Base-T
Power method PoE++
UL 294 Power Limited Class 2 Power Supply
UL 60950/62368 LPS/PS2
Max. power consumption Without PoE output: 30W
With PoE output: 50W
PoE input 50 VDC, 1 A
PoE output PoE passthrough, (4) PoE, 50V DC, 20W total
Button (1) Factory reset
LED System: white/blue
Output relays: white
Digital input Request to exit/Request to enter/Remote release/Door position sensor
Dry output relay Lock: 30V DC, 1A
Auxiliary: 30V DC, 1A
Output relay powered Lock: 12V DC, 1A
Auxiliary: 12V DC, 0.33A
12V DC, 0.33A
Operating environment For indoor use only
Ambient operating temperature 0 to 40 °C (32 to 104 °F)
Operating ambient humidity 5 to 95% non-condensing
UL Level 294 Destructive Attack: Level I
Line Security: Level I
Resistance: Level I
Backup power: Level I
UL 294 Declaration Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
The equipment is designed to comply with National Electrical Code Section, ANSI/NFPA 70, Article 725.121, Power Supplies for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Qualifying task: 1
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number and date of issue and/or revision level. UA-Hub002, V01 Gate
Wiring information
Wire Gauge (AWG) Requirements
Total length to device Output charging current at 12 V DC
100mA 250mA 500mA 1A
6.1 m (20 ft) 22 22 22 18
15.2 m (50 ft) 22 22 22 18
30.5 m (100 ft) 22 22 18 18

UACC-Cable-DoorLockRelay (18 AWG) is recommended.
PoE cabling requirements The minimum conductor size allowed to connect between the PSE or power injector and the PD must be 24 AWG (0.21 mm 2 ) for horizontal or vertical cable.
LED
PoE in Solid blue: Adopted/device is ready.
Solid white: pending adoption.
White/blue flashing: Updating firmware.
PoE output Off: Not connected or no data link
Solid blue: Connected and data link activated
UA-G2-Pro Mechanical
Dimensions 160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6 in)
Weight 136 grams (4.8 ounces)
Enclosure material polycarbonate, glass
Mounting material Aluminum alloy
Mounting Wall, gang box
Waterproofing IP55
Hardware
Network interface (1) GbE RJ45 port
Connectivity BLE 4.2
NFC
Power method PoE
UL 294 PSU Class 2 Power Limited
UL 60950-1/62368-1 PSU LPS/PS2
Supported voltage range 48 VDC
Max. power consumption 6W
ESD/EMP Protection Air: ±15kV, Contact: ±8kV
Sensor Proximity sensor
Camera 4000 x 3000, 12 MP, 30 FPS
Viewing angle Height: 96.67°, V: 123.15°, Depth: 153.11°
Microphone Yeah
Spokesman (1) 4 ohms, 1.5 W
LED R/G/B/N
Flash
Button (1) Factory reset
NFC frequency 13.56MHz
NFC reading range < 30 millimeters
NFC standards ISO 14443A, 14443B, 15693
NFC technology NFC tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environment outdoor use
Ambient operating temperature Device: -30 to 45° C (-22 to 113° F)
Display:* -10 to 45° C (14 to 113° F)
*The display will turn off when the ambient temperature is above or below the display's operating temperature, but other functions will still be functional. (Effective after firmware v1.3.28)
Operating ambient humidity 5 to 90% non-condensing
Program information The software version of a product can be checked at https://unifi.ui.com
UL Level 294 Destructive Attack: Level I
Line Security: Level I
Resistance: Level I
Backup power: Level I
UL 294 Declaration Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is designed to comply with National Electrical Code section, ANSI/NFPA 70, Article 725.121, Power Supplies for Class 2 and Class 3 Circuits.
PoE cabling requirements Cable 5e cabling is the minimum recommended performance category. The performance category used must match the transmission speed required at the installation site.
The minimum conductor size allowed for connection between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for connection cables; 24 AWG (0.21 mm 2 ) for horizontal or vertical cable.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number and date of issue and/or revision level. UA-G2-Pro/UA-G2-Pro-Black, V02
LED
System Solid blue: Adopted/device is ready.
Fixed white: pending adoption.
White/blue flashing: Updating firmware.
Flashing red: emergency lock.
UA-G2 Mechanical
Dimensions 93x40x36.5mm (3.7x1.6x1.4")
Weight 82 grams (2.9 ounces)
Enclosure material polycarbonate, glass
Mounting On the wall, gang box
Waterproofing IP55
Hardware
Network interface (1) 10/100 MbE RJ45 port
Connectivity BLE 4.1
Power method PoE
UL 294 PSU Class 2 Power Limited
UL 60950-1/62368-1 PSU LPS/PS2
Supported voltage range 48 VDC
Max. power consumption 5W
ESD/EMP Protection Air: ±15kV, Contact: ±8kV
Sensors Proximity sensor
Spokesman (1) 8 ohms, 0.7 W
LED R/G/B/N
Button (1) Factory reset
NFC frequency 13.56MHz
NFC reading range < 30 millimeters
NFC standards ISO 14443A, 14443B, 15693
NFC technology NFC tag 1,2,3,4,5
MIFARE Classic
MIFAREPlus
MIFARE Ultralight
MIFARE DESFire
Operating environment outdoor use
Ambient operating temperature -30 to 45 °C (-22 to 113 °F)
Operating ambient humidity 5 to 90% non-condensing
Program information The software version of a product can be checked at https://unifi.ui.com
UL Level 294 Destructive Attack: Level I
Line Security: Level I
Resistance: Level I
Backup power: Level I
UL 294 Declaration Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is designed to comply with National Electrical Code section, ANSI/NFPA 70, Article 725.121, Power Supplies for Class 2 and Class 3 Circuits.
PoE cabling requirements Cable 5e cabling is the minimum recommended performance category. The performance category used must match the transmission speed required at the installation site.
The minimum conductor size allowed for connection between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for connection cables; 24 AWG (0.21 mm 2 ) for horizontal or vertical cable.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number and date of issue and/or revision level. UA-G2/UA-G2-Black, V02
LED
System Solid blue: Adopted/device is ready.
Fixed white: pending adoption.
White/blue flashing: Updating firmware.
Flashing red: emergency lock.
UA- Pocket Mechanic
Dimensions 84x39x7.4mm (3.3x1.5x0.29")
Weight 16 grams (0.56 ounces)
Enclosure material Polycarbonate, stainless steel
Waterproofing IP54
Hardware
NFC frequency 13.56MHz
NFC technology ISO/IEC 14443 Type A
MIFARE DESFire EV3 4K
UniFi Access Proprietary Security Protocol
Ambient operating temperature -10 to 45 °C (14 to 113 °F)
Operating ambient humidity 10 to 90% non-condensing
Certification EC

Recently viewed:

SUSCRIBETE

Registrate con tu correo y recibe nuestras ofertas exclusivas.