Description
The OTDR 5000 is a handy optical time domain reflectometer available for 850/1300nm multimode measurements or as a combination unit for 850/1300nm multimode and 1310/1550nm singlemode.
The FiberXpert uses an optical time-domain reflectometer to send a pulse of light through the fiber and then measures the profile of the reflected signal to verify bend radius, splices, breaks, and connectors. Components, fault types, and distance to fault are graphically displayed on the FiberXpert.
The FiberXpert is a complete solution with 850/1300nm multimode and 1310/1550nm singlemode modes. For both multimode and singlemode fibers, the FiberXpert OTDR 5000 features a very high dynamic range with an event dead zone of less than 80 cm, making it a perfect tool for measuring short fiber distances in compliance with standards, for documentation and for detecting any errors.
- Level 2 measurement according to the fiber optic cabling standard.
- All events and stage analysis listed in a results table.
- Graphical representation of the reflectance curve for the length-dependent analysis of all reflection and attenuation events.
- Automatic analysis (pass/fail) of measurement results according to TIA/IEC limit values.
- Automatic recognition of macro curvatures.
- Integrated attenuation meter.
- Professional measurement protocols using eXport analysis software.
- Color touch screen.
- Optional fiberglass inspection microscope; includes adapter for most fiberglass connectors.
General (Typically at 25°C)
Weight 0.4 kg.
Dimensions (length × width × height) 128 x 134 x 40 mm.
Optical interfaces
-
- Interchangeable FC, SC, DIN and ST optical connectors .
Technical Features
-
- Laser Safety (21 CFR) Class 1.
- Distance units Kilometers, feet and miles.
- Group index range 1.300000 to 1.700000 in 0.00001 feet.
- Number of data points More than 128,000 data points.
- Distance measurements Automatic or dual cursor.
- Display range 3.25m to 260km.
- Cursor resolution 1 cm.
- Sampling Resolution Sampling Resolution
- Accuracy ±1 m ± 10-5 x distance ± sampling resolution (excluding
- group index uncertainties).
Mitigation measures
-
- Automatic, manual, 2-point, 5-point, and LSA
- Display range 1.25 dB to 55 dB.
- Display resolution 0.001 dB.
- Cursor resolution 0.001 dB.
- Linearity ±0.03 dB/dB.
- Threshold 0.01 to 5.99 dB in 0.01 dB steps.
Reflectance/ORL Measurements
-
- Reflectance accuracy ±2 dB.
- Display resolution 0.01 dB.
- Threshold −11 to −99 dB in 1 dB steps.
CW Source
-
- CW source output power level −3.5 dBm.
- Operating modes CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINTest.
Power meter
-
- MM power level range : −3 to −30 dBm.
- SM: −2 to −50 dBm.
- Calibrated wavelengths MM: 850 and 1300 nm.
- SM: 1310, 1490, 1550, 1625, 1650nm.
- MM measurement accuracy : ±1 dB (used in conditioning mode).
- SM: ±0.5 dB.
Multimode and Quad OTDR Modules (Typically at 25°C)
-
- Central wavelength (Laser at 25°C) MM: 850/1300 ±30 nm.
- SM: 1310/1550 ±20 nm.
- MM pulse width : 3 ns to 1 μs.
- SM: 3 ns to 20 μs.
- RMS MM dynamic range : 26/24 dB.
- SM: 37/35 dB.
- (the one-way difference between the level of backscatter
- extrapolated to the start of the fiber and the RMS noise level after
- (an average of 3 minutes).
- Dead zone of the MM event : 0.8 m.
- SM:0.9 m.
- (measured at ±1.5 dB from the peak of an unsaturated reflective event).
- MM dead zone attenuation :4 m.
- SM:4 m.
- (measured at ± 0.5 dB of linear regression using a reflectance
- (type F/UPC).