MIRCOM FX-400R Addressable fire alarm panel up to 240 points

Save 20%
SKU: FX-400R
No reviews

Price:
Sale priceS/. 5,361.00 PEN Regular priceS/. 6,701.00 PEN

Shipping calculated at checkout

Stock:
In stock
VER FICHA TÉCNICA

Description

The FX-400 is an addressable fire alarm control panel ideal for small to medium sized installations. The FX-400 is shipped pre-assembled with main board, power supply, transformer, main display, black back box and black cabinet with black or red door. Compatible with MGC devices (MIX-4000 Series) including photoelectric duct smoke detectors and multi-modules The FX-400 comes with one addressable loop (SLC) with a maximum of 240 MGC devices total. The FX-400 is equipped with a built-in telephone dialer (POT). The dialer provides a means of communicating panel status to the remote central monitoring station over two dedicated telephone lines.

Specs

Cabinet Dimensions
Dimensions of the
cabinet (less ring)
integrated trim)
14.5" Width x 4.25" Depth x 21" Height
(36.83cm x 10.79cm x 53.34cm)
Full dimension
from the cabinet
16.7" Width x 5.7" Depth x 23" Height
(42.42xm x 14.48 x 58.42cm)
Electrical Specifications
Power of
primary input
120VAC 60Hz / 240VAC 50Hz
1.81 Amp / 0.98 Amp (primary)
Battery Type 24 VDC
Gel cell / Sealed lead acid
Temperature and humidity ranges
Temperature of
operation
32°F to 120°F (0°C to 49°C)
Humidity 0 to 93% relative humidity
(non-condensing)

Characteristics

  • 4 x 20 LCD display.
  • Main Board, Power Supply and Backbox.
  • An addressable loop (SLC) with a maximum of 240 MGC devices (MIX-4000 series) in total.
  • Flexible zones and group configuration options allow for grouped entries and exits.
  • Compatible with MGC devices (MIX-4000 series) including photoelectric duct smoke detector and multiple modules.
  • Device sub-addressing saves physical address space for multiple modules, sounder bases, relay bases, and dual input modules.
  • Compatible with conventional detectors using the MGC MIX-4042 conventional zone module, see document LT-1023 for compatible detectors.
  • Class A, Class X, or Class B analog loop(s).
  • Four Class B, Class A power-limited NAC circuits (max 1.5 amps each - 5.0 amps total).
  • NAC circuits can be configured as silenceable signal, non-silenceable signal, silenceable strobes, non-silenceable strobes, or auxiliary power output. The audible signal can be Constant, Temporal Code, California Code, or March Time. Supports strobe synchronization protocols from all major manufacturers.
  • USB port on the main board for easy programming and firmware update via local keyboard or PC.
  • Configurable signal silence inhibition, automatic signal silence and one-man walk test.
  • Two-stage operations, alarm verification and positive alarm sequence.
  • Dedicated common alarm, supervisory, trouble and auxiliary alarm relays.
  • Additional outputs include connections for an RTI remote trouble indicator, a PR-300 reverse polarity module, an RS-485 bus for connection of up to seven RAX-LCD-LITE, RAM-3318-LCD, SRM-312 and RA-1000 series annunciators.
  • Built-in POT dialer allows events to be reported to a monitoring facility. The UDACT/digital communicator can be configured for single- or dual-line operation and utilizes Security Industry Association (SIA) and Ademco Contact ID protocols.
  • Full compatibility with Windows 10
  • The IPS-2424DS and IPS-4848DS shunt modules can be used when connected to this panel as remote annunciators.
    These modules are mounted in a series of enclosures and connected to the RAM-3318-LCD.
  • Two event history logs consisting of a 400-event alarm log for alarm-related events and a 400-event general log for all other events.
  • Buzzer Silence can be reused as an auxiliary reset
  • Addressable devices will not flash their LEDs when
    no blinking flag is enabled.
  • The current capability of each SLC is 200 mA standby and 400 mA alarm. SLC maximum line resistance 40 ohms and maximum line capacitance 0.47uF.
  • The Not Blinking indicator is reused to indicate that the device will not blink its LED.
  • Supports 4-20mA functionality on the MIX-4042 module.
  • Supports Suite auto mute.
  • Buzzer silence can be reused as auxiliary reset.
  • Dual relay module for operating independent relays.
  • Group bypass switch.